13% off
Fluke 1587/i400 Current Clamp FC Kit

Fluke 1587/i400 Current Clamp FC Kit

0
0
5
USD1,421.00
USD1,634.00
USD213.00(13%)
Estimated Lead Time : Usually ships in 1 - 10 working days.
FLK-1587/i400 FC Kit
Fluke
Brand New
12 months 

NII REF No : IAFD111611121121

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com.All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.

  • Estimated Lead Time : Usually ships in 1 - 10 working days.

  • Manufacturer : Fluke

  • Fluke 1587/i400 Current Clamp FC Kit

  • Includes the Fluke 1587 FC 2-in-1 Insulation DMM and the Fluke i400 Current Clamp
    With the Fluke 1587 FC, perform insulation tests, plus a wide-range of DMM tasks with confidence and ease
    Use the Fluke i400 with your Fluke 1587 FC to accurately measure AC current without breaking the circuit

  • The Fluke 1587 FC 2-in1 Insulation DMM
    Pl/DAR measurements with TrendIt™ graphs
    Memory storage through Fluke Connect Measurements app
    Temperature Compensation through Fluke Connect Measurements app
    VFD low-pass filter for accurate motor drive measurements
    Insulation test voltages 50 V, 100 V, 250 V, 500 V, 1000 V
    Insulation test voltages 500 V, 1000 V
    Insulation test: 0.01 MO to 2.0 GO
    Insulation test: 0.1 MO to 600 MO
    Auto-discharge of capacitive voltage
    Insulation test smoothing reading
    Frequency / Capacitance / Diode test / Temperature
    Min/Max / AC/DC Voltage / DC Millivolts / AC/DC Milliamps
    Resistance (0.1 O to 50 MO) / Continuity / Auto power off
    Three-year warranty / Remote probe, test leads, alligator clips, K-type thermocouple, hard case

  • Fluke i400 AC Current Clamp
    Use with your Fluke 1587 FC to measure 1A AC to 400 A AC
    1 mA/Amp output guarantees easy reading
    CAT III 1000 V / CAT IV 600 V overvoltage rating for added user protection
    Specially designed to offer maximum utility in a very compact shape
    Maximum conductor: Ø 32 mm
    1 year warranty

  • Includes the 1587 FC 2-in-1 Insulation DMM and the i400 Current Clamp

  • The Fluke 1587 FC Insulation Multimeter features four powerful new diagnostic functions through the Fluke Connect Measurements app:-
    Pl/DAR timed ratio tests with TrendIt™ graphs identifies moisture and contaminated insulation problems faster
    Memory storage through Fluke Connect eliminates writing down results, reduces errors and saves data for historical tracking over time
    Temperature Compensation through app for establishing accurate baselines and relevant historical comparisons
    Historical tracking and trending of assets identifies degradation over time, allows real-time decisions to be made in the field with Fluke Connect® Assets

  • The Fluke i400 AC CurrentClamp is a high-safety current clamp for digital multimeters. The current clamp provides accurate current measurements without breaking electric circuits, helping you take measurements safely with industry standard safety ratings.

  • Models: FLK-1587/i400 FC Kit

  • Fluke 1587/i400 Current Clamp FC Kit

  • Includes:
    Fluke 1587 FC 2-in-1 Insulation DMM
    Fluke i400 Current Clamp

  • Fluke 1587 FC Insulation Multimeter

  • Fluke 1587 FC Insulation Multimeter

  • Electrical Specifications

  • AC voltage measurement Range(600.0 mV):-
    -Resolution : 0.1 mV
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) : ±(2% + 3)

  • AC voltage measurement Range(6.000 V):-
    -Resolution : 0.001 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) : ±(2% + 3)

  • AC voltage measurement Range(60.00 V):-
    -Resolution : 0.01 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) : ±(2% + 3)

  • AC voltage measurement Range(600.0 V):-
    -Resolution : 0.1 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) : ±(2% + 3)¹

  • AC voltage measurement Range(1000 V):-
    -Resolution : 1 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(2% + 3)
    -Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) : ±(2% + 3)¹

  • ¹ 1 kHz bandwidth

  • Low-Pass Filter Voltage Range(600.0 mV):-
    -Resolution : 0.1 mV
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) : +(2% + 3), -(6% - 3)

  • Low-Pass Filter Voltage Range(6.000 V):-
    -Resolution : 0.001 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) : +(2% + 3), -(6% - 3)

  • Low-Pass Filter Voltage Range(60.00 V):-
    -Resolution : 0.01 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) : +(2% + 3), -(6% - 3)

  • Low-Pass Filter Voltage Range(600.0 V):-
    -Resolution : 0.1 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(1% + 3)
    -Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) : +(2% + 3), -(6% - 3)

  • Low-Pass Filter Voltage Range(1000 V):-
    -Resolution : 1 V
    -Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) : ±(2% + 3)
    -Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) : +(2% + 3), -(6% - 3)

  • DC Voltage Measurement

  • Range : Resolution : Accuracy ±(% of Rdg + Counts)

  • 6.000 V dc : 0.001 V : ±(0.09% + 2)

  • 60.00 V dc : 0.01 V : ±(0.09% + 2)

  • 600.0 V dc : 0.1 V : ±(0.09% + 2)

  • 1000 V dc : 1 V : ±(0.09% + 2)

  • Input impedance : 10 MO (nominal), <100 pF

  • Normal mode rejection ratio : >60 dB @ 50 Hz or 60 Hz

  • Common mode rejection ratio : >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)

  • Accuracies apply to ± 100% of range

  • DC Millivolts Measurement

  • Range : Resolution : Accuracy ±(% of Rdg + Counts)

  • 600.0 mVdc : 0.1 mV : ±(0.1% + 1)

  • DC and AC Current Measurement

  • AC 45 Hz to 1000 Hz

  • Range : 400 mA

  • Resolution : 0.1 mA

  • Accuracy ±(% of Rdg+Counts) : ±(1.5% + 2)¹

  • Burden voltage (Typical) : 2 mV/mA

  • Range : 60 mA 

  • Resolution : 0.01 mA 

  • Accuracy ±(% of Rdg+Counts) : ±(1.5% + 2)¹

  • Burden voltage (Typical) : 2 mV/mA

  • DC

  • Range : 400 mA

  • Resolution : 0.1 mA

  • Accuracy ±(% of Rdg+Counts) : ±(0.2% + 2)

  • Burden voltage (Typical) : 2 mV/mA

  • Range : 60 mA

  • Resolution : 0.01 mA

  • Accuracy ±(% of Rdg+Counts) : ±(0.2% + 2)

  • Burden voltage (Typical) : 2 mV/mA

  • Overload : 600 mA for 2 minutes maximum

  • Fuse protection for mA input : 0.44 mA, 1000 V, IR 10 kA

  • AC conversion : Inputs are ac-coupled and calibrated to the rms value of sine wave input

  • Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor =1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.

  • ¹ 1 kHz bandwidth

  • Ohms Measurement Range (600.0 O) : 0.1 O : ±(0.9% + 2)

  • Ohms Measurement Range (6.000 kO) : 0.001 kO : ±(0.9% + 2)

  • Ohms Measurement Range (60.00 kO) : 0.01 kO : ±(0.9% + 2)

  • Ohms Measurement Range (600.0 kO) : 0.1 KO : ±(0.9% + 2)

  • Ohms Measurement Range (6.000 MO) : 0.001 MO : ±(0.9% + 2)

  • Ohms Measurement Range (50.0 MO ²) : 0.01 MO : ±(1.5% + 3)

  • Overload protection : 1000 V rms or dc

  • Open circuit test voltage : <8.0 V dc

  • Short circuit current : <1.1 mA

  • ¹ Accuracies apply from 0% to 100% of range
    ² Up to 80% relative humidity

  • Diode Test

  • Diode test indication : Display voltage drop: 0.6 V at1.0 mA nominal test current:

  • Accuracy : ±(2% + 3)

  • Continuity Test

  • Continuity indication : Continuous audible tone for testresistance below 25 O and off above 100 O. Maximum Reading; 1000 O

  • Open circuit voltage : <8.0 V

  • Short circuit current : 1.0 mA typical

  • Overload protection : 1000 V rms

  • Response time : >1 m sec

  • Frequency Measurement Range 99.99 Hz : 0.01 HzResolution : ±(0.1%Rdg + 1Counts)

  • Frequency Measurement Range 999.9 Hz : 0.1 Hz Resolution : ±(0.1% Rdg + 1Counts)

  • Frequency Measurement Range 9.999 kHz : 0.001 kHz Resolution : ±(0.1% Rdg+ 1Counts)

  • Frequency Measurement Range 99.99 kHz : 0.01 kHzResolution : ±(0.1% Rdg+ 1Counts)

  • Frequency Counter Sensitivity

  • Frequency Counter Sensitivity (600.0 mV ac):-
    -V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz : 100.0 mV 
    -V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz : 150.0 mV 
    -DC Trigger Levels¹ to 20 kHz² : NA

  • Frequency Counter Sensitivity (6.0 V):-
    -V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz : 1.0 V 
    -V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz : 1.5 V 
    -DC Trigger Levels¹ to 20 kHz² : -400.0 mV and 2.5 V

  • Frequency Counter Sensitivity (60.0 V ):-
    -V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz : 10.0 V 
    -V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz : 36.0 V 
    -DC Trigger Levels¹ to 20 kHz² : 1.2 V and 4.0 V

  • Frequency Counter Sensitivity (600.0 V ):-
    -V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz : 100.0 V 
    -V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz : -
    -DC Trigger Levels¹ to 20 kHz² : 12.0 V and 40.0 V

  • Frequency Counter Sensitivity (1000.0 V ):-
    -V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz : 300.0 V 
    -V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz : -
    -DC Trigger Levels¹ to 20 kHz² : 12.0 V and 40.0 V

  • ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
    ² Usable to 100 kHz with full scale input

  • Capacitance Range (1000 nF ) : 1 nF Resolution | ±(1.2%Rdg + 2Counts)

  • Capacitance Range (10.00 µF ) : 0.01 µF Resolution | ±(1.2%Rdg + 2Counts)

  • Capacitance Range (100.0 µF ) : 0.1 µF Resolution | ±(1.2%Rdg ±90 counts)

  • Capacitance Range (9999 µF ) : 1 µF Resolution | ±(1.2% Rdg±90 counts)

  • Temperature Measurement

  • Range : Resolution : Accuracy ±(% of Rdg+Counts)¹

  • -40 ° C to 537 ° C : 0.1 °C : ±(1% + 10 counts)

  • -40 ° F to 998 ° F : 0.1 °F : ±(1% + 18 counts)

  • ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument

  • Insulation Specifications

  • Measurement range : 0.01 MO to 2 GO

  • Test voltages : 50, 100, 250, 500, 1000 V

  • Test voltage accuracy : +20%, -0%

  • Short-circuit test current : 1 mA nominal

  • Auto discharge : Discharge time <0.5 second for C = 1 µF or less

  • Live circuit detection : Inhibit test if terminal voltage > 30 V prior to initialization of test

  • Maximum capacitive load : Operable with up to 1 µF load

  • Output Voltage 50 V (0% to +20%):-
    -Display range : 0.01 to 6.00 MO
    -Resolution : 0.01 MO
    -Test current : 1 mA @ 50 kO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(3% + 5 counts)
    -Display range : 6.0 to 50.0 MO
    -Resolution : 0.1 MO
    -Test current : 1 mA @ 50 kO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(3% + 5 counts)

  • Output Voltage 100 V (0% to +20%):-
    -Display range : 0.01 to 6.00 MO
    -Resolution : 0.01 MO
    -Test current : 1 mA @ 100 kO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(3% + 5 counts)
    -Display range : 6.0 to 60.0 MO
    -Resolution : 0.1 MO
    -Test current : 1 mA @ 100 kO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(3% + 5 counts)
    -Display range : 60 to 100 MO 
    -Resolution : 1 MO
    -Test current : 1 mA @ 100 kO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(3% + 5 counts)

  • Output Voltage 250 V (0% to +20%):-
    -Display range : 0.1 to 60.0 MO 
    -Resolution : 0.1 MO
    -Test current : 1 mA @ 250 kO 
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)
    -Display range : 60 to 250 MO 
    -Resolution : 1 MO
    -Test current : 1 mA @ 250 kO 
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)

  • Output Voltage 500 V (0% to +20%):-
    -Display range : 0.1 to 60.0 MO
    -Resolution : 0.1 MO
    -Test current : 1 mA @ 500 kO 
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)
    -Display range : 60 to 500 MO
    -Resolution : 1 MO
    -Test current : 1 mA @ 500 kO 
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)

  • Output Voltage 1000 V (0% to +20%):-
    -Display range : 0.1 to 60.0 MO 
    -Resolution : 0.1 MO
    -Test current : 1 mA @ 1 MO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)
    -Display range : 60 to 600 MO 
    -Resolution : 1 MO
    -Test current : 1 mA @ 1 MO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(1.5% + 5 counts)
    -Display range : 0.6 to 2.0 GO 
    -Resolution : 100 MO 
    -Test current : 1 mA @ 1 MO
    -Resistance accuracy ±(% of Rdg + Counts) : ±(10% + 3 counts)

  • General Specifications

  • Maximum voltage applied to any terminal and common : 1000 V

  • Storage temperature : -40 °C to 60 °C (-40 °F to 140 °F)

  • Operating temperature : -20 °C to 55 °C (-4 °F to 131 °F)

  • Temperature coefficient : 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)

  • Relative humidity:-
    -Noncondensing
    -0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
    -0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
    -0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)

  • Vibration : Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

  • Radio frequency communication : 2.4 GHz ISM Band

  • Radio frequency certification : FCC: T68-FBLE, IC: 6627A-FBLE

  • Electromagnetic Compatibility 

  • International:-
    -IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
    -Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
    -Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
    -Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.

  • Korea (KCC):-
    -Class A Equipment (Industrial Broadcasting & Communication Equipment)
    -Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.

  • USA (FCC) : 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.

  • Enclosure protection : IEC 60529: IP40 (non-operating)

  • Safety

  • IEC 61010-1 : Pollution Degree 2

  • IEC 61010-2-033 : CAT IV 600 V / CAT III 1000 V

  • Batteries : Four AA batteries (NEDA 15A or IEC LR6)

  • Battery life : Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MO with a duty cycle of 5 seconds on and 25 seconds off.

  • Size (H x W x L) : 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

  • Weight : 550 g (1.2 lb)

  • Altitude:-
    -Operating : 2000 m
    -Storage : 12,000 m

  • Over-range capability : 110% of range except for capacitance which is 100%

  • Frequency overload protection : <107 V Hz

  • Fuse protection for mA input : 0.44A, 1000 V, IR 10 kA

  • Fluke i400 AC Current Clamp

  • Specifications

  • Nominal current range : 400 A

  • Continuous current range : 1 A - 400 A

  • Maximum non-destructive current : 1000 A

  • Lowest measurable current : 1 A

  • Basic accuracy:-
    -2% + 0.06 A
    -(45-400 Hz)
    -(% reading + floorspec)

  • Useable frequency : 5 Hz - 20 kHz

  • Output level(s) : 1 mA/A

  • Safety Specifications

  • Safety : CAT IV 600 V, CAT III, 1000 V

  • Maximum voltage : 1000 V AC rms from earth to ground, in compliance with EN61010

  • Mechanical and General Specifications

  • Warranty : 1 year

  • Maximum conductor diameter : 32 mm (1.25 in)

  • Maximum conductor size (busbar) : 750 MCM

  • Output cable length : 1.5 m (59 in)

  • Shrouded banana plugs : Yes

  • Shipping Weight : 2.6 Kg

[short_review]
[long_review]
Did you find this helpful?  [rev_helpful] of [rev_votes] Found Helpful
Reviewed by: (Verified Buyer)  from [user_city]. [user_email] on [review_date]
[rating]
There are no reviews for this product!

Reward Points

1421 points will be rewarded to you when you buy this item.

Related Items

https://www.nexinstrument.com/assets/images/5_thumbnail.png

Feature 5

Price USDX1.4=USD SELLING PRICE|161221Alexcalculate(costX1.2X1.6=sellingprice)

Recently Viewed Items

Legal Disclaimer

NEX Instrument Inc is not an authorized dealer, agent or associate of any of the designers, brands, or manufacturers, the products of which are offered for sale on www.nexinstrument.com. All trademarks, brand names, and logos mentioned are used for identification purposes only and are registered trademarks of their respective owners who reserve the right of ownership. The use of trademark, brand name or product on our website is not intended to suggest that the company, trademark or brand is affiliated to or endorses our website. All items are 100% authentic and legally purchased from authorized sources.